We provide an immediate response to clean agent fire suppression system discharges, whether accidental or from a fire, to get your system back into service as quickly as possible. Fm200 is a colorless, nontoxic gas perfectly suited to protect high value assets in areas that may be normally occupied, in locations where cleanup of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an. Costeffective protection for highvalue assets highvalue assets such as data and sensitive equipment demand the quality fire suppression offered by the hygood fm 200 fire suppression system. A list of systems of similar nature and scope shall be provided at the.
And it discharges in 10 seconds or less, extinguishing a fire quickly and. That translates into minimal equipment facility damage and little or no business interruption. Bosch security conventional fire panel 500 series basics of fire detection duration. Electrical actuators are used for system actuation and can be reset reducing the number of components to be replaced during service after discharge. After receiving the fire signal, fm 200 is discharged totally from the cylinders within 10 seconds to fill up the space uniformly at the design concentration to extinguish the fire. Aug 28, 2000 fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. The system shall be a total flood fm200 suppression system supplied by pyrochem. Safe for use in occupied areas at the design concentration, the system helps protect critical. After an fm200 system discharge, the fm200 cylinders should be returned to an authorized chemetron filling location for recharge. Service for fm200 systems western states fire protection can help to design, install, and provide ongoing service for your fm200 system.
Fire protection design with fm 200 part 2 of 2 this website requires certain cookies to work and uses other cookies to help you have the best experience. A minimum of five years experience in the design, installation, and testing of fm200 fire suppression systems. Whether you need portable fire equipment, service and maintenance, or largescale fire suppression systems for mining, marine, industrial, commercial and retail use, gielle has got you covered. While doing data center design, adequate arrangement should consider to protect hardware and data of datacenter from any force majeure conditions like fire, flood, earthquake.
Once the fm200 fire suppression system discovers a fire in the room, the fm200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from getting out of control. Acoma drive, suite 106 scottsdale, az 85260 usa telephone. The fm 200 fire suppression system contains sensitive detectors that can detect even the smallest fires. Visual indications shall be provided at the control panel as follows. A typical case of protecting a power station using the fm 200 total suppression system is the basis for the following design information. The fm200 system is ideal for areas occupied by personnel and containing assets that could be. Tanks are charged with fm200 in increments of two pounds in a small tank or three pounds in a larger tank for a custom installation without unnecessary expense. Using innovative technology, the iflow fire suppression system is a stateoftheart delivery system that provides a regulated and effective discharge of inert gas clean agent. Fm 200 design course we provide fire suppression engineers with autocad drawings for fm 200 project, they are. Jul 31, 2017 hydraulic flow calculation program chem200 the next step in system design is to provide the necessary design parameters to the computer program to numerically model the fm200 system accurately. The symbol identifies conditions that can result in damage to the opener or its components, serious injury, or death. The ansul fm200 fire suppression system protects what matters most, your people and your critical data and equipment. Typically fm200 requires a design concentration of 7%, which is well below the 9% no observable adverse effect level noael on cardiac sensitisation.
Fike corporation 704 south 10th street blue springs, mo. Trim components trim components complete the installation of the fm200 system and. All fm200 systems are to be built from system compatible components approved for use by the supplier and certified to bs5750 parts 1 and 2. A the system shall be a total flood fm200 suppression system supplied by. Fm200 fire suppression system for fire protection incontrol.
Nfpa 2001, clean agent fire extinguishing system, is the governing code for designing the system, and nfpa 72, national fire alarm code, is followed for fixing the fire alarm system, an. The system shall be total flooding fm200 extinguishing system designed to provide a uniform concentration of 7%, at normal average ambient temperature, minimum of fm200. Dupont fm200 fire suppression systems american fire. The program, chem200, has been written within the windows environment. Fire detection and fm200 suppression system interstate fire. The detection circuits can be configured using cross, counting. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing. Fm200 total flooding fire suppression system data specification sheet general the fm200 fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. Our clean agent fire extinguishing system utilizes fm200 as the extinguishing medium. The system shall provide a fm200 minimum design concentration of 7.
Hygood systems utilise genuine fm gas manufactured by dupont, novec fire protection fluid hygkod 3m and provide full traceability of the original gas fill, thus giving peace of mind to the end user. The minimum design requirements for total flooding fire protection systems employing new clean agents are set forth in nfpa2001 in a manner analogous to. The primary extinguishing mechanism of fm200 is heat absorption, with a secondary chemical contribution from the thermal decomposition of fm200 in the flame. Fm200 clean agent fire suppression system hfc227 fike. Download fm 200 firefighting project autocad drawings for free. System level 2, or above, who will be responsible for the project. Utilizing the industry recognized fm200 suppression agent, amerex has. Nov 07, 20 clean agent fire suppression system clean agent extinguishing system fm 200. The fm200 fire suppression system is an engineered system utilizing a fixed nozzle. Free download now fm 200 calculation program from mep work.
Per nfpa requirements, fm200 is designed for a 10 second discharge time. Obtain medical attention if soreness or redness persists. Step 1 identify the hazard to protect and note the applicable design concentration number. Fm200calculator design calculation sheet project no. Clean agent fire suppression system clean agent extinguishing system fm200. Fm200 has good flow characteristics and can be designed for modular or manifolded combined system use.
It doesnt leave any residue after release or cause damage to it equipment and documents. Lpg fm200 high pressure 42 bar clean agent fire suppression systems. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing systems. Provide proof of ability to recharge the fm200 system within 24 hours after a. Fm200 is not a direct replacement for existing halon 1 installations due to the difference in agent quantity and discharge characteristics the minimum fm200 design concentration for class a hazards is 6 4% for ul listed systems or 7 17% for fm approved systems, and for class b hazard is at least 9 0%. Once the fm 200 fire suppression system discovers a fire in the room, the fm 200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from getting out of control. Fm 200 is a colorless, nontoxic gas perfectly suited to protect high value assets in areas that may be normally occupied, in locations where cleanup of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an. Feb 17, 2016 fm200 distribution components distribution components consist of the discharge nozzles used to introduce the fm200 agent into a protected hazard along with the associated piping system used to connect the nozzles to the cylinder assembly. Pdf fm200 ecs series engineered fire suppression systems.
Control rooms, telecommunications rooms, museum or store goods or property of. Further information the fm200 system is part of the kidde family of fire protection components designed and manufactured to the highest standards of quality and reliability. The system shall be total flooding fm 200 extinguishing system designed to provide a uniform concentration of 7%, at normal average ambient temperature, minimum of fm 200. The design of such a system requires that the fm200 chemical agent be discharged from its container within 10 seconds and be thoroughly mixed throughout the protected volume, reaching a minimum.
Fire systemstm w ith a chemetron fire systems fm200 system in control, you are assured of fast, efficient and environmentally safe fire extinguishment. After an fm 200 system discharge, the fm 200 cylinders should be returned to an authorized chemetron filling location for recharge. Fikes clean agent system with fm 200 also known as hfc227ea, uses fikes patented rupture disc valve design offering additional flexibility, effectiveness and speed. When you consider the potentially devastating environmental effects of an uncontrolled fire, its easy to see that an fm200 system is an important. The initial will typically be slightly larger than the design concentration due to over filling to ensure at least the design concentration is available when the system discharges since there might be some leakage from the agent container. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. The fm 200 system is ideal for areas occupied by personnel and containing assets that could be damaged by water. No facility can afford the loss of time, money or productivity that occurs after a fire. There is no residue after the release of a fm200 system. The fm 200 system is most effective when used with the autopulse detection system to introduce the clean agent rapidly. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion. The ansul fm200 clean agent fire suppression system is approved and listed by underwriters laboratories ul for class a, b and c fires. The hold time is defined as the time for the initial concentration to fall to cmin.
The system shall be a total flood fm 200 suppression system supplied by pyrochem. Typical areas that can be protected by a fm200 system are. The fm200 system is ideal for areas occupied by personnel and containing assets that could be damaged by water. Lpg carbon dioxide fire protection systems are available for use in total flooding or local fire protection applications making it an effective fire protection system for a wide variety of hazards. Fm200 fire suppression system costeffective protection. A good design on developing uniform distribution of fm200 clean agent, and improvement in existing building fm200 system will be proposed. Fikes clean agent system with fm200 also known as hfc227ea, uses fikes patented rupture disc valve design offering additional flexibility, effectiveness and speed. Precautions and warnings in this manual are identified with this warning symbol. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Nov 05, 2009 fm 200 fire suppression systems go to.
All components of the clean agent fire extinguishing system shall be the products of the same manufacturer or listed by that manufacturer as compatible with those devices, components and equipment. Clean fire extinguishing systems, fm 200 systems are suitable to be used for the fire that occurred in an area equipped with high value electrical and electronic equipment is an important part of doing business, such as a computer room. Hydraulic flow calculation program chem200 the next step in system design is to provide the necessary design parameters to the computer program to numerically model the fm200 system accurately. First aid measures eyes immediately flood the eye with plenty of warm water for at least 15 minutes, holding the eye open. To schedule fm 200 system services in the new jersey or delaware area, contact confires online or call 888 2280917. Never give anything by mouth to an unconscious person. The fm200 fire suppression system contains sensitive detectors that can detect even the smallest fires.
Fm200 fire suppression system multron systems pte ltd. A administration archive fm200 total flooding quantity approved by. Have an fm200 recharging station on the contractors premises. Amongst all gaseous suppression systems, fm 200 system design is most commonly use. Fm200 total flooding fire suppression system general the fm200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Aug 25, 2000 a typical case of protecting a power station using the fm 200 total suppression system is the basis for the following design information. Our clean agent fire extinguishing system utilizes fm 200 as the extinguishing medium. Fm200 fire suppressant hfc227ea can be safely used where people are present. Data center always equipped with high valued hardware and precision data. Fm200 works by interrupting the fire triangle at the molecular level, is odorless, and nonconductive. The software is designed b y mostafa elwakeel and he gave us the rights to publish it. A the system shall be a total flood fm 200 suppression system supplied by.
Fire suppression system and fire protection fluid gielle. Fm200 fire suppression system costeffective protection for. Hygood is renowned for first class product development, design and ensuring our systems are industry approved. Kidde clean agent fire extinguishing system employing chemoursfm200 december 2015 page 2 of 6 d. Control rooms, telecommunications rooms, museum or store goods or property. As was discussed in part 1 of this article in the august pme, fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. Total flooding is the only approved application method for fm200 systems. The system shall provide a fm 200 minimum design concentration of 7. Costeffective protection for highvalue assets highvalue assets such as data and sensitive equipment demand the quality fire suppression offered by the hygood fm200 fire suppression system. Nfpa 2001, standard on clean agent fire extinguishing systems, 2000 edition the amount of halocarbon agent required to achieve the design concentration shall be calculated from the. Fm200 total flood fire suppression systems design, installation, and maintenance manual one.
Our passion to protect drives us to create solutions to help you safeguard. When used at standard design concentrations, it is safe for occupied spaces. Fm200 works to quench fires in seconds and hold damage to a minimum. Product overview fm200 fire suppression system clean agent power protects people and property n nonconductive and will not shortout electronic equipment or thermally shock detects fire in early stages n suppresses class a, b and c fires n less visual obscuration and minimal risk to personnel n colorless, odorless clean agent leaves no residue n electrically nonconductive. The amount of oxygen must be constant and nonrenewable.
Tanks are charged with fm 200 in increments of two pounds in a small tank or three pounds in a larger tank for a custom installation without unnecessary expense. The ansul fm 200 clean agent fire suppression system is approved and listed by underwriters laboratories ul for class a, b and c fires. Clean fire extinguishing systems, fm200 systems are suitable to be used for the fire that occurred in an area equipped with high value electrical and electronic equipment is an important part of doing business, such as a computer room. Data center design companies spend millions to protect datacenter specially from fire. Data center fire suppression systems fm 200 system design.